Directional (CPE) Antennas
MT-404021/S 3.3-3.8 GHz 17 dBi DUAL POLARIZED DIRECTIONAL ANTENNA |
|
|
ELECTRICAL |
REGULATORY COMPLIANCE |
ETSI EN 302 085 V.1.1.1 (2000-06) TS1-TS5 Range 1
|
FREQUENCY RANGE |
3.3-3.8 GHz
|
GAIN |
17 dBi (min)
|
VSWR |
1.5 : 1 (typ), 2.0:1 (max)
|
POLARIZATION |
Dual Vertical & Horizontal
|
3dB ELEVATION BEAMWIDTH |
18°(typ)
|
3dB AZIMUTH BEAMWIDTH |
18°(typ)
|
F/B RATIO |
30 dB
|
CROSS POLARIZATION |
25dB (max)
|
PORT TO PORT ISOLATION |
25 dB (max)
|
POWER |
1W (max)
|
INPUT IMPEDANCE |
50 (ohm)
|
LIGHTNING PROTECTION |
DC Grounded
|
MECHANICAL |
DIMENSIONS (LxWxD) |
305x305x25mm (max)
|
CONNECTOR |
2 x SMA Female
|
WEIGHT |
1.5 (kg) (max)
|
MOUNTING KIT |
MT-120018
|
RADOME MATERIAL |
Plastic, White
|
BASE PLATE MATERIAL |
Aluminum with chemical conversion coating
|
OUTLINE DRAWING |
See Below
|
|
ENVIRONMENTAL |
TEST |
STANDARD |
DURATION |
TEMPERATURE |
NOTES |
LOW TEMPERATURE |
IEC 68-2-1 |
72 h |
-55°C |
|
HIGH TEMPERATURE |
IEC 68-2-2 |
72 h |
+71°C |
|
TEMP. CYCLING |
IEC 68-2-14 |
1 h |
-45°C +70°C |
3 Cycles |
VIBRATION |
IEC 60721-3-4 |
30 min/axis |
|
Random4M3 |
SHOCK MECHANICAL |
IEC 60721-3-4 |
|
|
4M3 |
HUMIDITY |
ETSI EN300-2-4 T4.1E |
144 h |
|
95% |
WATER TIGHTNESS |
IEC 529 |
|
|
IP67 |
SOLAR RADIATION |
ASTM G53 |
2000h |
|
|
FLAMMABILITY |
UL 94 |
|
|
Class HB |
SALT SPRAY |
IEC 68-2-11 Ka |
500h |
|
|
ICE AND SNOW |
|
|
|
25mm Radial |
WIND SPEED SURVIVAL OPERATION |
|
|
|
220 Km/h
160 Km/h | |
Azimuth Radiation Pattern Midband
Freq. 3.5 GHz |
Elevation Radiation Pattern Midband
Freq. 3.5 GHz |
|
| |
.jpg)
|
WAIVER! While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists. | |